- Please choose product options by visiting U-Blot® Influenza A virus (H5N1) HA/Hemagglutinin Antibody.
U-Blot™ Tabletop High-speed Refrigerated Micro Centrifuge
Product details
Product introduction
Ideal for centrifugation of temperature-sensitive samples, such as live cells, animal tissues or proteins. It allows them to be used in a multitude of applications, including pelleting of DNA and RNA samples, pelleting of PCR amplified nucleic acids, separation of antibody and protein precipitates, performing enzymatic tests, removing cell debris from cell homogenates, and achieving bacterial and yeast cell fractionation.
Product advantage
- Electronic Magnetic door locking system – the lid can be closed with one hand soft touch
- Precooling, the compressor automatically starts cooling as long as the set temperature is lower than the ambient temperature
- Sound indicator at the end of running.
- Temperature can be set, rangingfrom -20℃ to 40℃.
- Short pre-cooling time of only 7minutes from room temperature to 4℃
- Up to 9 program storage capacity 3-layer sealed rotors ensure safe centifugation
- High-strength aluminum alloy rotor can be fully autoclavable at 121
- With rotor imbalance detection alarm, ensure safe and effective centrifugation.
- Adjustable acceleration/deceleration at 9 levels allows gentle braking at low speed for better separation
- Five rotors with 0.2mL, 0.5mL, 1.5mL, 2mL and 5mL centrifuge tubes/ PCR tubes capacity
- An external condensation tank prevents water accumulation within the centrifuge chamber
RCF calculation
Relative centrifugal force (RCF)can be calculated using the following formula:
RCF=1.118×r×n2×10-5
r-rotation radius, unit: cm; n-rotation speed, unit- rpm
Specifications
| Maximum rotation speed | 15,000rpm(200-15,000rpm) step: 100rpm |
| Maximum relative centrifugal acceleration | 21,380×g, step: 10×g |
| Capacity | 1.5/2ml×24; 0.5ml×36; PCR8 tube bank ×4; 5ml×12; 5ml×18; |
| Temperature setting range | Tabletop high-speed refrigerated micro-centrifuge: -20℃-40℃ |
| Timing | 30s-99 min; HOLD (continuous running) |
| Drive motor | DC brushless motor |
| Safety performance | Dual door locks, overspeed, overtemperature and Internal diagnosis system. |
| Power | Single phase |
| 220-230V,5A, 50/60Hz, 400W | |
| 110-120V,5A,50/60Hz,490W | |
| Dimensions (mm) | (L) 332× (W) 553× (H) 283 |
| Weight | 30kg |
| Acceleration and deceleration time | 25s↑25s↓ |
| Noise | ≤56dB |
| Other functions | Rotation speed/RCF switchover, inching operation, running process indication and sound reminder; 9-step acceleration, 9-step deceleration; stored program capability. |
Please login to post questions